{"product_id":"scheda-comandi-per-scopa-aspirapolvere-vorwerk-folletto-vk140-vk150","title":"Control panel for Vorwerk Folletto VK140 VK150 vacuum cleaner","description":"Electronic button module designed for the control panel of the indicated Vorwerk electric brooms. The board, code VAC600VK, constitutes the interface circuit used to transmit start and activation commands. This electric broom control PCB can be useful to replace a button board that no longer correctly recognizes the power-on commands or temporary power increase. Compatible with the models listed at the end of the page.\u003cbr\u003e\u003cbr\u003eTechnical specifications\u003cbr\u003e- SKL adaptable spare part\u003cbr\u003e- MPN (Manufacturer Part Number): VAC600VK\u003cbr\u003e- Country of production: Made in China\u003cbr\u003e- Color: green\u003cbr\u003e- Compatible series (check the models under compatibility): Folletto VK140, VK150\u003cbr\u003e- What's included: PCB board with connection terminal block\u003cbr\u003e- Equivalent or obsolete codes: 02064, 30825, 32089, 233.590.011-10, 2078.5101\u003cbr\u003e\u003cbr\u003eDimensions manually checked by the PG Service team\u003cbr\u003e- Width 147mm\u003cbr\u003e- Length 78mm\u003cbr\u003e- Maximum height 27.5mm\u003cbr\u003e\u003cbr\u003eSpare part explanations\u003cbr\u003eThe electronic control board in a vacuum broom serves to detect the pressure of the buttons and transmit the user's request to the appliance's electronics. When the power button is pressed, the button module communicates the request to start or stop the broom to the electronic management.\u003cbr\u003eAn efficient control board must transmit the signals without interruptions, false contacts, or intermittent responses.\u003cbr\u003e\u003cbr\u003eSymptoms, what problems can you solve by replacing the electronic control board\u003cbr\u003e- The electric broom does not turn on when pressing the button? A microswitch or the button module could be faulty, although the same symptom can depend on the battery or other parts of the electronics.\u003cbr\u003e- Does the power button work only by pressing it several times? An irregular button response can indicate control wear, contact oxidation, or an electronic circuit problem.\u003cbr\u003e- Does the broom turn on or off without a regular button press? A deteriorated microswitch, a damaged board, or an unstable connector can cause abnormal responses from the power system.\u003cbr\u003e- Does the control work only by moving or pressing the panel area? If the operation changes by applying pressure to the panel, it is appropriate to check the wiring, connectors, and integrity of the button board.\u003cbr\u003e- Was the board replaced but the broom still does not turn on? The fault could depend on the wiring, motor, sensors, or another electronic board of the appliance.\u003cbr\u003e\u003cbr\u003eCare and maintenance of the spare part\u003cbr\u003eThe electronic control module is normally protected inside the appliance and does not require direct periodic interventions. Clean the buttons externally with a dry or slightly damp cloth, avoiding sprays and liquids near the openings. If the appliance is disassembled for maintenance, check that the board connectors are clean, intact, and correctly inserted. Do not attempt improvised repairs on the electronic tracks without proper tools and skills.\u003cbr\u003e\u003cbr\u003eInstallation instructions\u003cbr\u003e- Carefully remove the outer plastics to reach the electronic module without forcing plastics, wiring, or connectors.\u003cbr\u003e- Before removal, note the position of each connection to avoid errors during reassembly.\u003cbr\u003e- Carefully free the electrical connections avoiding damaging terminals, tracks, or wiring.\u003cbr\u003e- Remove the original control board from its supports and install the new module in the same position.\u003cbr\u003e- Reconnect all connectors ensuring they are inserted all the way and in the correct position.\u003cbr\u003e\u003cbr\u003eTips from the PG Service assistance center\u003cbr\u003eBefore replacing the electronic board, it is advisable to check the condition of the motor, wiring, connectors, and handle controls, as some malfunctions can present symptoms similar to those caused by a faulty board.\u003cbr\u003eDuring replacement, always disconnect the appliance from the electrical network and carefully check the correct insertion of all connections before reassembly.\u003cbr\u003eSince it is an electronic component involved in the management of the motor and the power supply of the broom, we recommend entrusting the diagnosis and replacement to qualified technical personnel, so as to avoid damage to the new board or other components.\u003cbr\u003e\u003cbr\u003eIs that not what you are looking for?\u003cbr\u003eIn addition to the spare control board, we have hundreds of original Vorwerk accessories and spare parts available in our store, if you cannot find what you need through independent browsing you can contact us anytime, we will respond within a few hours even during holidays and weekends. And if a product is not available, we will do everything possible to find it and order it exclusively for you. With us you can find much more besides spare parts for Vorwerk electric brooms!\u003cbr\u003e\u003cbr\u003eCompatibility (is it right for my product?)\u003cbr\u003eThis control module is verified for use on the following Vorwerk electric broom models. Always check the identification label of your appliance to be sure you are choosing the right part for your model. If you are not sure, ask our support:\u003cbr\u003e\u003cbr\u003eFolletto \/ Kobold\u003cbr\u003eVK140\u003cbr\u003eVK150","brand":"SKL","offers":[{"title":"Default Title","offer_id":66415137587549,"sku":"VAC600VK","price":66.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0622\/1165\/3812\/files\/VAC600VK.jpg?v=1794047904","url":"https:\/\/pmnservice.com\/en\/products\/control-board-for-vacuum-cleaner-vorwerk-folletto-vk140-vk150","provider":"PGService","version":"1.0","type":"link"}